Chemical and process analysts require gas mixtures with precisely known, accurate, and certified component concentration levels with the maximum possible degree of confidence and reliability for standardizing and calibrating their instruments.
Each such gas mixture is designed and manufactured to meet tight specifications with reference to blending tolerance, analytical accuracy, traceability, and stability, keeping in mind the safety in the preparation and use of such gas mixtures.
Our calibration gas mixtures are prepared using the highest quality components and are certified to international standards. We offer a wide range of standard calibration gas mixtures for common applications, as well as custom blends for specific requirements. Our experienced team can work with you to create a custom gas mixture that meets your exact specifications.
In addition to calibration gas mixtures, we also offer a range of specialty gases for niche applications. These include ultra-high purity gases, reactive gases, and rare gases. Our specialty gases are used in a variety of industries, from semiconductor manufacturing to medical research and aerospace.
Various Mixture Grades of Calibration Gas Mixture Standards
Mixture Grade | Blend Method | Preparation Tolerance | Certification Accuracy | Certification | Traceability |
---|---|---|---|---|---|
TGPL special Primary | Gravimetric | 5 To 50% Composition +/- 1 % 1 ppm to 5 % +/- 2% | +/- 1% | Single or Dual | SRM, Weight |
TGPL Primary | Gravimetric | 5 To 50% Composition +/- 1 % 500 PPM to 5% +/- 2% 1 ppm to 500 ppm +/-5% |
+/- 1% | Single | Weight |
Special Certified | Gravimetric or Partial Pressure | 5% | +/- 2% | Single or Dual | SRM, Weight TGPL Primary Standards |
Certified | Gravimetric or Partial Pressure | 10 % to 20 % | +/- 2% | Single | SRM, Weight TGPL Primary Standards |
Industries Automobile
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For Engine Emission Testing | Carbon Monoxide gas | 0-500 ppm | Nitrogen/ Air |
For Engine Tuning | Carbon Dioxide gas | 0-500 ppm | Nitrogen/ Air |
Nitric Oxide gas | 0-500 ppm | Nitrogen | |
Nitrogen Dioxide gas | 0-500 ppm | Nitrogen/Air | |
Sulphur Dioxide + Nitrogen | 0-500 ppm | Nitrogen/Air | |
Hexane gas | 0-500 ppm | Nitrogen/Air | |
Propane gas | 0-500 ppm | Nitrogen/Air | |
Propane + Carbon Monoxide |
0-500 ppm | Nitrogen/Air | |
Propane + Carbon Monoxide + Carbon Dioxide |
0-500 ppm | Nitrogen/Air | |
Carbon Monoxide + Carbon Dioxide + Nitrogen |
0-500 ppm | Nitrogen |
Thermal Power
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For Analytical Instruments | Oxygen gas | 0-10% | Nitrogen |
Carbon Monoxide gas | 0-500 ppm | Nitrogen | |
Methane gas | 0-10 % | Argon | |
Carbon Monoxide + Oxygen | 0-500 ppm | Nitrogen | |
Hydrogen gas | 0-10 % | Nitrogen |
Cement
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For Analytical Instruments | Oxygen | 0-8 % | Nitrogen |
Calibration | Carbon Monoxide | 0-5 % | Nitrogen |
Methane | 0-5 % | Argon | |
Carbon Monoxide | 0-5 % | Nitrogen |
Steel Industry
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For Process |
P10 – Methane + Argon Carbon Monoxide + Oxygen |
10% 0-500 ppm 0-10 % |
Argon Nitrogen |
For calibration of Instruments | Hydrogen+ Nitrogen+ Methane + Carbon MonoxideCarbon Dioxide – balance |
50 % Hydrogen+ 1.5% Nitrogen+3.5 % Methane + 25.5 % Carbon MonoxideCarbon Dioxide – balance |
Carbon Dioxide |
For calibration of Instruments | Ethane + Propane + Iso-Butane + N-Butane + Iso-Pentane + N-Pentane + Hexane + Carbon Dioxide + Nitrogen +Balance Methane |
1.8% Ethane + 1.0% Propane + 0.2 % Iso-Butane + 0.1 % N-Butane + 0.1% Iso-Pentane + 0.1% N-Pentane + 0.03% Hexane + 1.5 % Carbon Dioxide + 0.5% Nitrogen + Balance Methane |
Methane |
Petrochemicals & Refineries
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For Calibrating online gas chromatogram For Explosimeter |
Oxygen Carbon Dioxide Methane N-Butane |
0-10 % 0-10 % 2.5% 0.8% |
Nitrogen Nitrogen Air Air |
For Explosimeter |
Hydrogen 1-Hexene + Ethylene + Nitrogen Ethylene + Methane + Hydrogen Ethylene + Ethene + 1- |
2% 1-Hexene 0.8% + Ethylene 2.0 % + Nitrogen Ethylene 50ppm + Methane 40 % + Hydrogen Ethylene 9.96% + Ethene 4.95 % + 1-Butene 0.499 % + Iso – Pentane 0.497 % |
Air Nitrogen Hydrogen Nitrogen |
Oil and Natural
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For Calibrating online Gas Chromatograms |
Hydrogen + Carbon Dioxide + Carbon Monoxide + Methane + Ethane +Ethylene + Propane + Propylene + Iso Butane + Propadiene + N Butane + Trans 2 Butane + 1 Butene + Iso Butene+ CIS-2-Butene + ISO Pentane + 1,2 –Butadiene + N Pentene + 1,3 – Butadiene +Trans 2 Pentene + ISO Pentene + 1- Pentene + CIS 2 Pentene + Balance Nitrogen |
2.0000% Hydrogen + 1.0300% Carbon Dioxide + 0.5100% Carbon Monoxide + 1.4100% Methane + |
Nitrogen |
Nuclear Power
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
Oxygen + Nitrogen + Argon + Hydrogen + MethaneHydrogen |
0-5% 8% |
Helium Nitrogen |
Optic Fibre
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
Deuterium | 20% | Nitrogen |
Medical And Healthcare
Applications | Component | Concentration | Balance Gas |
---|---|---|---|
For calibrating Blood Gas Mixture |
Oxygen Carbon Dioxide |
20% 5% |
Nitrogen |
Pulmonary Function Test |
Carbon Dioxide Oxygen |
20% 5% |
Nitrogen |
Oxygen Uptake | Oxygen | 20% | Nitrogen |
Sterilisation Mixture | Ethylene Oxide + Nitrogen | 1% | Nitrogen |
Clinical Use | Ethylene Oxide +Nitrogen | 1% | Nitrogen |
Eximer Laser for eye surgery | 4% Carbon Monoxide + 5% Carbon Dioxide + | 4% Carbon Monoxide + 5% Carbon Dioxide + 13.5 % | Helium |
13.5 % Nitrogen + Helium | Nitrogen + Helium | ||
Lung Diffusion Test Mixtures-These mixtures are used in Pulmonary function tests & To calibrate apparatus which measures the amount of carbon Monoxide diffused through healthy versus unhealthy lungs | 0.1% Carbon Monoxide + 21% Oxygen + Nitrogen 0.3 % Carbon Monoxide + 10% Helium + 21 % Oxygen + Nitrogen | 0.1% Carbon Monoxide + 21% Oxygen + Nitrogen 0.3 % Carbon Monoxide + 10% Helium + 21 % Oxygen + Nitrogen | Nitrogen |
Fertilizer and Chemical Industry
Application | Component | Conentration | Balance Gas |
---|---|---|---|
For calibrating online analysers, Gas Chromatographs, Process use mixtures | Ammonia + Nitrogen Carbon Dioxide + Methane + Carbon Monoxide + Nitrogen Hydrogen + Nitrogen |
As per customer requirements | |
For Rubber Chemicals | Chlorine + Nitrogen | 10 ppm | Nitrogen |
Hydrogen+Nitrogen | 2% | Nitrogen | |
Applications | Component | Concentration | Balance Gas |
For calibrating Blood Gas Mixture |
Oxygen Carbon Dioxide |
20% 5% |
Nitrogen |
Pulmonary Function Test |
Carbon Dioxide Oxygen |
20% 5% |
Nitrogen |
Oxygen Uptake | Oxygen | 20% | Nitrogen |
Sterilisation Mixture | Ethylene Oxide + Nitrogen | 1% | Nitrogen |
Clinical Use | Ethylene Oxide +Nitrogen | 1% | Nitrogen |
Eximer Laser for eye surgery | 4% Carbon Monoxide + 5% Carbon Dioxide + | 4% Carbon Monoxide + 5% Carbon Dioxide + 13.5 % | Helium |
13.5 % Nitrogen + Helium | Nitrogen + Helium | ||
Lung Diffusion Test Mixtures-These mixtures are used in Pulmonary function tests & To calibrate apparatus which measures the amount of carbon Monoxide diffused through healthy versus unhealthy lungs | 0.1% Carbon Monoxide + 21% Oxygen + Nitrogen 0.3 % Carbon Monoxide + 10% Helium + 21 % Oxygen + Nitrogen | 0.1% Carbon Monoxide + 21% Oxygen + Nitrogen 0.3 % Carbon Monoxide + 10% Helium + 21 % Oxygen + Nitrogen | Nitrogen |
Water treatment
Application | Component | Concentration | Balance Gas |
---|---|---|---|
The use of carbon dioxide to control the pH levels of alkaline wastewater, cooling water, drinking water, and industrial process water systems. Carbon dioxide, a mildly acidic | Carbon Dioxide + Nitrogen | 1% | Nitrogen |
Laser Industry
Application | Component | Concentration | Balance Gas |
---|---|---|---|
Mixtures used in Laser Applications | |||
For Eximer Lasers | Hydrogen Chloride + Helium Hydrogen + Hydrogen Chloride + Helium |
Hydrogen Chloride 1-10% + Helium Hydrogen 1% + Hydrogen Chloride 5%+ Helium |
Helium |
For Molecular Laser Application | Carbon Dioxide + Nitrogen + Helium Balance | 4-16% Carbon Dioxide + 10-20% Nitrogen + Helium Balance | Helium |